Cart summary

You have no items in your shopping cart.

Human Bcl2 antagonist of cell death (BAD) ELISA Kit

Catalog Number: orb1146801

DispatchUsually dispatched within 5-10 working days
$ 300.00
Catalog Numberorb1146801
CategoryAssays and Kits
DescriptionThe test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Bcl2 antagonist of cell death(BAD). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Bcl2 antagonist of cell death(BAD). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Bcl2 antagonist of cell death(BAD), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Bcl2 antagonist of cell death(BAD) in the samples is then determined by comparing the OD of the samples to the standard curve.
ReactivityHuman
Range0.16-10 ng/mL
Assay Time3.5h
Concentration10 ng/mL
UniProt IDQ92934
Sensitivity0.056 ng/mL
Alternative namesLGALS3, CBP35, GALBP, GALIG, MAC2, 35 kDa lectin,
Read more...
NoteFor research use only
Application notesstandard: 10 ng/mL. Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human BAD. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human BAD. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human BAD, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human BAD in the samples is then determined by comparing the OD of the samples to the standard curve
Sample Typesserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Expiration DatePlease enquire.
Human Bcl2 antagonist of cell death (BAD) ELISA Kit

  • Human BAD ELISA Kit [orb563179]

    Human

    0.156-10ng/ml

    0.094ng/ml

    48 T, 96 T
  • Human Bcl-xl ELISA Kit [orb405653]

    Human

    0.156 ng/mL-10 ng/mL

    0.039 ng/mL

    10 x 96 T, 5 x 96 T, 48 T, 96 T, 24 T
  • Human Bcl2 Associated Death Promoter (BAD) ELISA Kit [orb2809898]

    Human

    78-5000pg/mL

    38.7pg/mL

    48 T, 96 T