Cart summary

You have no items in your shopping cart.

    F(ab')2 Human IgG (H&L) antibody

    F(ab')2 Human IgG (H&L) antibody

    Catalog Number: orb348214

    DispatchUsually dispatched within 5-10 working days
    $ 394.00
    Catalog Numberorb348214
    CategoryAntibodies
    DescriptionF(ab')2 Human IgG (H&L) antibody
    Species/HostDonkey
    ClonalityPolyclonal
    Tested applicationsELISA, IHC, WB
    ReactivityHuman
    IsotypeIgG F(ab')2
    ImmunogenHuman IgG whole molecule
    Concentration1.0 mg/mL
    Dilution rangeELISA: 1:20,000, IHC: 1:1,000-1:5,000, WB: 1:2,000-1:10,000
    Form/AppearanceLiquid (sterile filtered)
    PurityThis product was prepared from monospecific antiserum by immunoaffinity chromatography using Human IgG coupled to agarose beads followed by solid phase adsorption(s) to remove any unwanted reactivities, pepsin digestion and chromatographic separation. Assay by immunoelectrophoresis resulted in a single precipitin arc against anti-Donkey Serum, Human IgG, and Human Serum. No reaction was observed against anti-Pepsin, anti-Donkey IgG F(c), or Bovine, Chicken, Goat, Guinea Pig, Hamster, Horse, Mouse, Rabbit, Rat, and Sheep Serum Proteins.
    ConjugationUnconjugated
    StorageStore vial at -20° C or below. Avoid cycles of freezing and thawing. Centrifuge product if not completely clear after standing at room temperature. This product is stable for several weeks at 4° C as an undiluted liquid. Dilute only prior to immediate use.
    Buffer/Preservatives0.01% (w/v) Sodium Azide
    Alternative namesDonkey F(ab')2 Anti-Human IgG Antibody, Donkey Fab
    Read more...
    NoteFor research use only
    Application notesSuitable for immunomicroscopy and flow cytometry or FACS analysis as well as other antibody based fluorescent assays requiring extremely low background levels, absence of F(c) mediated binding, lot-to-lot consistency, high titer and specificity. The maximum amount of reagent required to stain 1 x 10E6 cells in flow cytometry is approximately 1.0 µg of antibody. Lesser amounts of reagent may be sufficient for staining. Optimal titers for other applications should be determined by the researcher. As a general guideline dilutions of 1:100 to 1:250 should be suitable for most applications.
    Expiration Date12 months from date of receipt.
    Submit a review

    Filter by Rating

      • Star
      • Star
      • Star
      • Star
      • Star
      • 5 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 4 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 3 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 2 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 1 stars