Antigen Coating Buffer, 5X

SKU: orb1821208

Description

Antigen Coating Buffer maximizes the adsorption of antigens onto polystyrene plates and stabilizes their 3-D structure to enhance specific signal, reduce reagent consumption, and extend the shelf-life of coated plates.

Images & Validation

Application Notes
1. Dilute Antigen Coating Buffer, 5X 1:5 using deionized water and mix for 15 minutes. As Antigen Coating Buffer is a 5X concentrate, crystalline precipitates may form in the bottle, especially when refrigerated. If this happens, gently warm the buffer until all crystals are dissolved. Do not let it boil., 2. Dilute your antigen into the coating buffer. Optimal coating concentration varies significantly from 0.2 µg/mL to 10 µg/mL., 3. Let the solution stir 10 – 15 minutes and pipette onto the plate. Optimal coating volume generally ranges from 50 – 200 µL per well. ICT recommends coating antibodies onto Immulon II HB plates., 4. Once added to the plate, incubate the coating solution from 8 – 24 hours at room temperature protected from light. Minimize evaporation by individually covering each plate with a plate sealing cover, wrapping a stack in plastic wrap, or placing plates in a humidified storage box and covering. , 5. After incubation, dump or aspirate the coating solution out of the wells., 6. Wash the plate twice with ICT’s ELISA Wash Buffer., 7. Aspirate and pipette one of ICT’s Blocking Buffers onto the plate at a higher volume than the coating solution (300 – 400 µL per well)., 8. Once added to the plate, incubate the block buffer from 8 – 24 hours at room temperature protected from light. Minimize evaporation by individually covering each plate with a plate sealing cover, wrapping a stack in plastic wrap, or placing plates in a humidified storage box and covering., 9. Aspirate the block buffer., 10. The assay can be run at this point, or the plate can be dried and packaged for later use., 11. Dry the plate by letting it sit in the fume hood covered with foil overnight, or dry in a drying chamber under vacuum from 3 – 6 hours at room temperature. When dry, seal the plate in an air-tight foil pouch with a desiccant and store at 2-8°C protected from light.

Key Properties

Storage & Handling

StorageRoom temp
Concentration5 X
Expiration Date12 months from date of receipt.
DisclaimerFor research use only

Similar Products

Quality Guarantee

Quality Guarantee

Explore bioreagents carefree to elevate your research. All our products are rigorously tested for performance. If a product does not perform as described on its datasheet, our scientific support team will provide expert troubleshooting, a prompt replacement, or a refund. For full details, please see our Terms & Conditions and Buying Guide. Contact us at [email protected].

Documents Download

Datasheet
Product Information
Download

Request a Document

Protocol Information

Antigen Coating Buffer, 5X (orb1821208)

  • Star
  • Star
  • Star
  • Star
  • Star
  • 0.0
Based on 0 reviews

Participating in our Biorbyt product reviews program enables you to support fellow scientists by sharing your firsthand experience with our products.

Login to Submit a Review

No reviews yet

Available Sizes

Select a size below

100 ml
$ 160.00
DispatchUsually dispatched within 5-10 working days
Bulk Enquiry