You have no items in your shopping cart.
You have no items in your shopping cart.
| Catalog Number | orb2302681 |
|---|---|
| Category | Antibodies |
| Description | This Multi-rAb antibody targets Rabbit IgG (H+L) in IHC. It is higly specific to rabbit IgG and shows minimal reactivity for mouse, rat, human, pig and bovine IgGs. |
| Clonality | Recombinant |
| Species/Host | Goat |
| Conjugation | HRP |
| Reactivity | Rabbit |
| Form/Appearance | Liquid |
| Concentration | Ready to use |
| Buffer/Preservatives | TBST+10 mg/mL rAlbumin+1 mg/mL gelatin + 0.1% proclin300 |
| Purity | Protein G purification |
| Tested applications | IHC |
| Dilution range | Ready to use |
| Antibody Type | Recombinant Antibody |
| Storage | Store at 2-8°C. Stable for one year after shipment. |
| Note | For research use only |
| Expiration Date | 12 months from date of receipt. |

Immunohistochemical analysis of paraffin-embedded rat brain tissue slide using (TDP43 recombinant antibody) at dilution of 1:4000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-Rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded mouse colon tissue slide using (smooth muscle actin recombinant antibody) at dilution of 1:10000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded rat colon tissue slide using (smooth muscle actin recombinant antibody) at dilution of 1:10000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection

Immunohistochemical analysis of paraffin-embedded mouse skeletal muscle tissue slide using (Dystrophin polyclonal antibody) at dilution of 1:10000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded mouse colon tissue slide using (E-cadherin polyclonal antibody) at dilution of 1:5000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded mouse skin tissue slide using (E-cadherin polyclonal antibody) at dilution of 1:5000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded human liver tissue slide using (TMEM173/STING antibody) at dilution of 1:2000. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded human tonsillitis tissue slide using commercial IVD grade KI67 antibody. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded human colon cancer tissue slide. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded human lymphoma tissue slide. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.

Immunohistochemical analysis of paraffin-embedded rat ovary tissue slide using (RCAS1 antibody) at dilution of 1:1000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse cerebellum tissue slide using (RCAS1 antibody) at dilution of 1:1000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded rat skeletal muscle tissue slide using (Dystrophin antibody) at dilution of 1:10000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer. Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse tongue tissue slide using (Dystrophin antibody) at dilution of 1:10000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse skin tissue slide using (E-cadherin antibody) at dilution of 1:5000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded human placenta tissue slide using (E-cadherin antibody) at dilution of 1:5000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded rat brain tissue slide using (TDP-43 antibody) at dilution of 1:4000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse brain tissue slide using (TDP-43 antibody) at dilution of 1:4000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded human placenta tissue slide using (TDP-43 antibody) at dilution of 1:4000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse spleen tissue slide using (F4/80 antibody) at dilution of 1:5000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse skeletal muscle tissue slide using (Dystrophin antibody) at dilution of 1:10000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded mouse liver tissue slide using (F4/80 antibody) at dilution of 1:5000 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection. The staining was performed on Celnovte's CNT360-M1 autostainer.

Immunohistochemical analysis of paraffin-embedded human breast cancer tissue slide. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0). Multi-rAb Polymer HRP-Goat anti-rabbit Recombinant secondary antibody orb2302681 was used for detection.
Participating in our Biorbyt product reviews program enables you to support fellow scientists by sharing your firsthand experience with our products.
Login to Submit a Review