Cart summary

You have no items in your shopping cart.

    CD2, CD7 antibody (FITC, PE)

    Catalog Number: orb198126

    DispatchUsually dispatched within 5-10 working days
    $ 538.00
    Catalog Numberorb198126
    CategoryAntibodies
    DescriptionMouse Polyclonal antibody to CD2, CD7 (FITC, PE)
    Species/HostMouse
    Tested applicationsFACS
    ReactivityHuman
    ImmunogenCD2=Derived from the hybridization of mouse Sp2/0 myeloma cells with spleen cells from BALB/c mice immunized with t lymphocytes activated by mixed lymphocyte culture. CD7=Derived from the hybridization of mouse P3-X63-Ag8.653 myeloma cells with spleen cells of BALB/c mice immunized with T-acute lymphoblastic leukemia (T-ALL) cells.
    ConcentrationTitered for flow cytometry
    Form/AppearanceProvided as solution in phosphate buffered saline with 0.08% sodium azide and 0.2% carrier protein
    ConjugationFITC/RPE
    Hazard InformationThis product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals.
    UniProt IDP06729, P09564
    StorageProduct should be stored at 4-8°C. DO NOT FREEZE
    Buffer/PreservativesProvided as solution in phosphate buffered saline with 0.08% sodium azide and 0.2% carrier protein
    Alternative namesCD2 FITC - CD7 PE
    Read more...
    NoteFor research use only
    Application notesPBMC: Add10 µl of MAB/10^6 PBMC in 100 µl PBS. Mix gently and incubate for 15 minutes at 2º to 8ºC. Wash twice with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. WHOLE BLOOD: Add10 µl of MAB /100 µl of whole blood. Mix gently and incubate for 15 minutes at room temperature 20ºC. Lyse the whole blood. Wash once with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. See instrument manufacturer’s instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope.
    Expiration Date12 months from date of receipt.
    CD2, CD7 antibody (FITC, PE)

    Flow cytometric analysis of Peripheral blood lymphocytes using CD2, CD7 antibody (FITC, PE)

    Submit a review

    Filter by Rating

      • Star
      • Star
      • Star
      • Star
      • Star
      • 5 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 4 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 3 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 2 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 1 stars