Cart summary

You have no items in your shopping cart.

Aurora A/AURKA Antibody

SKU: orb1290027

Description

Anti-Aurora A/AURKA Antibody. Tested in ELISA, Flow Cytometry, IHC, WB applications. This antibody reacts with Human.

Images & Validation

Tested ApplicationsELISA, FC, IHC, WB
ReactivityHuman
Application Notes
Western blot, 0.25-0.5 μg/ml, Human Immunohistochemistry(Paraffin-embedded Section), 2-5 μg/ml, Human Flow Cytometry (Fixed), 1-3 μg/1x106 cells, Human ELISA, 0.1-0.5 μg/ml, -. Adding 0.2 ml of distilled water will yield a concentration of 500 μg/ml

Related Conjugates & Formulations

Key Properties

Antibody TypePrimary Antibody
HostRabbit
ClonalityPolyclonal
IsotypeRabbit IgG
ImmunogenE.coli-derived human Aurora A/AURKA recombinant protein (Position: K23-S403).
Molecular Weight46 kDa
PurificationImmunogen affinity purified.

Storage & Handling

StorageMaintain refrigerated at 2-8°C for up to 2 weeks. For long term storage store at -20°C in small aliquots to prevent freeze-thaw cycles.
Form/AppearanceLyophilized
ConcentrationAdding 0.2 ml of distilled water will yield a concentration of 500 μg/ml.
DisclaimerFor research use only

Alternative Names

Probable ATP-dependent RNA helicase DDX58; 3.6.4.13; DEAD box protein 58; RIG-I-like receptor 1; RLR-1; Retinoic acid-inducible gene 1 protein; RIG-1; Retinoic acid-inducible gene I protein; RIG-I; DDX58

Similar Products

  • Aurora A/AURKA Antibody [orb865684]

    ELISA,  FC,  ICC,  IF,  IHC,  WB

    Human

    Rabbit

    Polyclonal

    Unconjugated

    100 μg
  • Goat anti-Aurora kinase A / AURKA Antibody [orb18316]

    ELISA,  IP,  WB

    Human

    Goat

    Polyclonal

    Unconjugated

    100 μg
  • Aurora-A Antibody [orb1263547]

    FC,  IF,  WB

    Human

    Polyclonal

    Unconjugated

    400 μl
  • Aurora A AURKA Rabbit Monoclonal Antibody [orb547188]

    FC,  ICC,  IF,  WB

    Human, Mouse

    Rabbit

    Monoclonal

    Unconjugated

    100 μl
  • AURKA Recombinant Monoclonal Antibody [orb688940]

    ELISA,  IF

    Human

    Monoclonal

    Unconjugated

    50 μl, 100 μl
Quality Guarantee

Quality Guarantee

Explore bioreagents carefree to elevate your research. All our products are rigorously tested for performance. If a product does not perform as described on its datasheet, our scientific support team will provide expert troubleshooting, a prompt replacement, or a refund. For full details, please see our Terms & Conditions and Buying Guide. Contact us at [email protected].

Aurora A/AURKA Antibody

Flow Cytometry analysis of HepG2 cells using anti-Aurora A/AURKA antibody. Overlay histogram showing HepG2 cells (Blue line). To facilitate intracellular staining, cells were fixed with 4% paraformaldehyde and permeabilized with permeabilization buffer. The cells were blocked with 10% normal goat serum. And then incubated with rabbit anti-Aurora A/AURKA Antibody (1 µg/1x10^6 cells) for 30 min at 20°C. DyLight®488 conjugated goat anti-rabbit IgG (5-10 µg/1x10^6 cells) was used as secondary antibody for 30 minutes at 20°C. Isotype control antibody (Green line) was rabbit IgG (1 µg/1x10^6) used under the same conditions. Unlabelled sample without incubation with primary antibody and secondary antibody (Red line) was used as a blank control.

Aurora A/AURKA Antibody

IHC analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Aurora A/AURKA was detected in a paraffin-embedded section of human breast cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-Aurora A/AURKA Antibody overnight at 4°C. Peroxidase Conjugated Goat Anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using HRP Conjugated Rabbit IgG Super Vision Assay Kit with DAB as the chromogen.

Aurora A/AURKA Antibody

IHC analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Aurora A/AURKA was detected in a paraffin-embedded section of human cervical cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-Aurora A/AURKA Antibody overnight at 4°C. Peroxidase Conjugated Goat Anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using HRP Conjugated Rabbit IgG Super Vision Assay Kit with DAB as the chromogen.

Aurora A/AURKA Antibody

IHC analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Aurora A/AURKA was detected in a paraffin-embedded section of human lung adenocarcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-Aurora A/AURKA Antibody overnight at 4°C. Peroxidase Conjugated Goat Anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using HRP Conjugated Rabbit IgG Super Vision Assay Kit with DAB as the chromogen.

Aurora A/AURKA Antibody

IHC analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Aurora A/AURKA was detected in a paraffin-embedded section of human ovarian cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-Aurora A/AURKA Antibody overnight at 4°C. Peroxidase Conjugated Goat Anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using HRP Conjugated Rabbit IgG Super Vision Assay Kit with DAB as the chromogen.

Aurora A/AURKA Antibody

IHC analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Aurora A/AURKA was detected in a paraffin-embedded section of human renal oncocytoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-Aurora A/AURKA Antibody overnight at 4°C. Peroxidase Conjugated Goat Anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using HRP Conjugated Rabbit IgG Super Vision Assay Kit with DAB as the chromogen.

Aurora A/AURKA Antibody

IHC analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Aurora A/AURKA was detected in a paraffin-embedded section of human squamous cell carcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-Aurora A/AURKA Antibody overnight at 4°C. Peroxidase Conjugated Goat Anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using HRP Conjugated Rabbit IgG Super Vision Assay Kit with DAB as the chromogen.

Aurora A/AURKA Antibody

Western blot analysis of Aurora A/AURKA using anti-Aurora A/AURKA antibody. Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 30 ug of sample under reducing conditions. Lane 1: human Hela whole cell lysates, Lane 2: human CACO-2 whole cell lysates, Lane 3: human SiHa whole cell lysates. After electrophoresis, proteins were transferred to a nitrocellulose membrane at 150 mA for 50-90 minutes. Blocked the membrane with 5% non-fat milk/TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-Aurora A/AURKA antigen affinity purified polyclonal antibody at 0.5 µg/mL overnight at 4°C, then washed with TBS-0.1% Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:5000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for Aurora A/AURKA at approximately 46 kDa. The expected band size for Aurora A/AURKA is at 46 kDa.

UniProt Details

No UniProt data available

Documents Download

Datasheet
Product Information
Download

Request a Document

Protocol Information

WB
Western Blot (IB, immunoblot)
View Protocol
IHC
Immunohistochemistry
View Protocol
FC
Flow Cytometry
View Protocol
ELISA
Enzyme-linked Immunosorbent Assay (EIA)
View Protocol

Aurora A/AURKA Antibody (orb1290027)

  • Star
  • Star
  • Star
  • Star
  • Star
  • 0.0
Based on 0 reviews

Participating in our Biorbyt product reviews program enables you to support fellow scientists by sharing your firsthand experience with our products.

Login to Submit a Review

No reviews yet

Available Sizes

Select a size below

100 μg
$ 500.00
DispatchUsually dispatched within 2-4 weeks
Bulk Enquiry