RadChemDosi Cell Survival Assay Kit

Catalog Number: orb342313

DispatchUsually dispatched within 5-10 working days
$ 670.00
Catalog Numberorb342313
CategoryAssays and Kits
DescriptionRadChemDosi Cell Survival Assay Kit
ConjugationUnconjugated
StorageStore Kit at 2-8° C prior to opening. See kit insert for complete instructions.
Alternative namesRadiation dosing assay, Gamma radiation assay, dos
Read more...
NoteFor research use only
Application notesRadChemDosi Cell Survival Assay Kit contains enough reagents for 100 test if 1 ml is used for irradiation. RadChemDosi is sensitive to measure the dose rate as low as 2.5Gy/min at various positions in a Cesium irradiator chamber. In addition to calibrating the dose rate at each position in a radiation chamber periodically, it can also be used to measure the dose rate in each well of a 6 and 24 wells plate.
Expiration DatePlease enquire.
RadChemDosi Cell Survival Assay Kit

RadChemDosi™ Cell Survival Assay to measure gamma radiation dose rate by producing free radicals that reacts with biomolecules in mammalian and other types of cells. y = 0.043x + 0.000 r2 = 0.998; y = 0.014x + 0.003 r2 = 0.990; y = 0.010x + 0.004 r2 = 0.945. Dose rate with turn table on: Position 1- 1193.82 rads/min or 11.92 Gy/min. Position 2- 388.36 rads/min or 3.88 Gy/min. Position 3- 277.4 rads/min or 2.774 Gy/min.

RadChemDosi Cell Survival Assay Kit

RadChemDosi™ is an effective way to measure dose rate for ionizing radiation. In addition to calibrating the dose rate at each position in a radiation chamber periodically, it can also be used to measure the dose rate in each well of a 6 and 24 wells plate. Measurment of gamma dose rate with RadChemDosi™ in 6 well plates. Dose Rate with the turntable on: Position 2- 360.28 rads/min or 3.60 Gy/min for each well. y = 0.013x + 0.000 r2 = 1.000 (each).

RadChemDosi Cell Survival Assay Kit

RadChemDosi™ is sensitive to measure the dose rate as low as 2.5 Gy/min at various positions in a Cesium irradiator chamber. The variation in radiation dose rate measured in each of the six well plate in a radiation machine with no turntable suggests that the dose rate calibration by RadDose assay is required to accurately measure the dose given to cells in each well of a six well plate. The calibration by RadDose is essential in radiation chambers without turntable. y = 0.047x + 0.015 r2 = 0.970; y = 0.072x + 0.022 r2 = 0.972; y = 0.040x + 0.013 r2 = 0.977; y = 0.033x - 0.003 r2 = 0.980; y = 0.028x + 0.002 r2 = 0.999; y = 0.031x - 0.001 r2 = 0.971.