Cart summary

You have no items in your shopping cart.

COL6A1 Antibody

Catalog Number: orb865617

Select Product Size
SizePriceQuantity
100 μg$ 500.00
100 μg Enquire
DispatchUsually dispatched within 2-4 weeks
Product Properties
Catalog Numberorb865617
CategoryAntibodies
DescriptionAnti-COL6A1 Antibody. Tested in ELISA, IHC, WB applications. This antibody reacts with Human.
ClonalityPolyclonal
Species/HostRabbit
IsotypeRabbit IgG
ConjugationUnconjugated
ReactivityHuman
Form/AppearanceLyophilized
ConcentrationAdding 0.2 ml of distilled water will yield a concentration of 500 μg/ml.
PurificationImmunogen affinity purified.
ImmunogenE.coli-derived human COL6A1 recombinant protein (Position: Q20-G1028).
UniProt IDP12109
MW140 kDa
Tested applicationsELISA, IHC, WB
Application notesWestern blot, 0.1-0.25 μg/ml, Human Immunohistochemistry(Paraffin-embedded Section), 1-2 μg/ml, Human ELISA, 0.1-0.5 μg/ml, -. Adding 0.2 ml of distilled water will yield a concentration of 500 μg/ml
Cross ReactivityNo cross-reactivity with other proteins.
Antibody TypePrimary Antibody
StorageMaintain refrigerated at 2-8°C for up to 2 weeks. For long term storage store at -20°C in small aliquots to prevent freeze-thaw cycles.
Alternative namesCytokine receptor common subunit beta; GM-CSF/IL-3
Read more...
NoteFor research use only
Expiration Date12 months from date of receipt.
Images
COL6A1 Antibody

IHC analysis of COL6A1 using anti-COL6A1 antibody. COL6A1 was detected in a paraffin-embedded section of human colonic adenocarcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-COL6A1 Antibody overnight at 4°C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

COL6A1 Antibody

IHC analysis of COL6A1 using anti-COL6A1 antibody. COL6A1 was detected in a paraffin-embedded section of human esophageal squamous carcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-COL6A1 Antibody overnight at 4°C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

COL6A1 Antibody

IHC analysis of COL6A1 using anti-COL6A1 antibody. COL6A1 was detected in a paraffin-embedded section of human gastric adenocarcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-COL6A1 Antibody overnight at 4°C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

COL6A1 Antibody

IHC analysis of COL6A1 using anti-COL6A1 antibody. COL6A1 was detected in a paraffin-embedded section of human gastric adenocarcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-COL6A1 Antibody overnight at 4°C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

COL6A1 Antibody

IHC analysis of COL6A1 using anti-COL6A1 antibody. COL6A1 was detected in a paraffin-embedded section of human placenta tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-COL6A1 Antibody overnight at 4°C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

COL6A1 Antibody

IHC analysis of COL6A1 using anti-COL6A1 antibody. COL6A1 was detected in a paraffin-embedded section of human renal clear cell carcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml rabbit anti-COL6A1 Antibody overnight at 4°C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

COL6A1 Antibody

Western blot analysis of COL6A1 using anti-COL6A1 antibody. Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 30 ug of sample under reducing conditions. Lane 1: human HCCT tissue lysates, Lane 2: human HCCP tissue lysates. After electrophoresis, proteins were transferred to a nitrocellulose membrane at 150 mA for 50-90 minutes. Blocked the membrane with 5% non-fat milk/TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-COL6A1 antigen affinity purified polyclonal antibody at 0.25 µg/mL overnight at 4°C, then washed with TBS-0.1% Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:5000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for COL6A1 at approximately 140 kDa. The expected band size for COL6A1 is at 109 kDa.

Similar Products
  • COL6A1 Antibody (C-term) [orb1929960]

    FC,  IF,  IHC-P,  WB

    Human, Mouse

    Rabbit

    Polyclonal

    Unconjugated

    50 μl, 100 μl
  • Collagen VI alpha 1 Rabbit Polyclonal Antibody [orb5898]

    IF,  IHC-Fr,  IHC-P,  WB

    Rabbit

    Human, Mouse, Rat

    Rabbit

    Polyclonal

    Unconjugated

    100 μl, 50 μl, 200 μl
  • Mouse Collagen Type VI Alpha 1 (COL6a1) ELISA Kit [orb780024]

    Mouse

    0.63-40 ng/mL

    0.197 ng/mL

    48 T, 96 T
  • Human Collagen Type VI Alpha 1 (COL6a1) ELISA Kit [orb776947]

    Human

    62.5-4000 pg/mL

    24.6 pg/mL

    96 T, 48 T
  • Rat Collagen Type VI Alpha 1 (COL6a1) ELISA Kit [orb780822]

    Rat

    0.16-10 ng/mL

    0.06 ng/mL

    48 T, 96 T
Reviews

COL6A1 Antibody (orb865617)

  • Star
  • Star
  • Star
  • Star
  • Star
  • 0.0
Based on 0 reviews

Participating in our Biorbyt product reviews program enables you to support fellow scientists by sharing your firsthand experience with our products.

Login to Submit a Review

No reviews yet