Cart summary

You have no items in your shopping cart.

    CD45R0 antibody (PE)

    Catalog Number: orb44556

    DispatchUsually dispatched within 5-10 working days.
    $ 513.00
    Catalog Numberorb44556
    CategoryAntibodies
    DescriptionMouse Monoclonal to CD45R0.
    ClonalityMonoclonal
    Clone NumberUCHL1
    Tested applicationsFC
    ReactivityHuman
    IsotypeMouse IgG2a
    ImmunogenHuman IL-2 dependent T cells
    Dilution rangeFlow cytometry: The reagent is designed for analysis of human blood cells using 20 μl reagent / 100 μl of whole blood or 106 cells in a suspension. The content of a vial (2 ml) is sufficient for 100 tests.
    PurityPurified antibody is conjugated with R-phycoerythrin (PE) under optimum conditions. Unconjugated antibody and free fluorochrome are removed by size-exclusion chromatography.
    ConjugationPE
    TargetCD45R0
    StorageStore at 2-8°C. Protect from prolonged exposure to light. Do not freeze.
    Buffer/PreservativesStabilizing phosphate buffered saline (PBS), pH 7.4, 15 mM sodium azide
    Alternative namesAnti-CD45R0 antibody
    Read more...
    NoteFor research use only
    Application notesFlow cytometry: The reagent is designed for analysis of human blood cells using 20 μl reagent / 100 μl of whole blood or 106 cells in a suspension. The content of a vial (2 ml) is sufficient for 100 tests.
    Expiration Date12 months from date of receipt.
    CD45R0 antibody (PE)

    Flow cytometry multicolor surface staining of human lymphocytes stained using anti-human CD45R0 (UCHL1) PE antibody (20 µl reagent / 100 µl of peripheral whole blood) and anti-human CD45RA (MEM-56) APC antibody (10 µl reagent / 100 µl of peripheral whole blood).

    CD45R0 antibody (PE)

    Separation of human CD45R0 positive CD45RA negative lymphocytes (red-filled) from CD45R0 negative CD45RA positive lymphocytes (black-dashed) in flow cytometry analysis (surface staining) of peripheral whole blood stained using anti-human CD45R0 (UCHL1) PE antibody (20 µl reagent / 100 µl of peripheral whole blood).

    CD45R0 antibody (PE)

    Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD45R0 (UCHL1) PE antibody (20 µl reagent / 100 µl of peripheral whole blood).

    • CD45R0 Antibody (PE/Cy7) [orb1993556]

      FC

      Human

      Monoclonal

      PE/Cy7

      100 tests
    Submit a review

    Filter by Rating

      • Star
      • Star
      • Star
      • Star
      • Star
      • 5 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 4 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 3 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 2 stars
      • Star
      • Star
      • Star
      • Star
      • Star
      • 1 stars