You have no items in your shopping cart.
You have no items in your shopping cart.
Catalog Number | orb738491 |
---|---|
Category | Antibodies |
Description | Anti-SHMT1 Antibody (monoclonal, 9C7). Tested in Flow Cytometry, IF, IHC, ICC, WB applications. This antibody reacts with Human, Monkey, Mouse, Rat. |
Species/Host | Mouse |
Clonality | Monoclonal |
Clone Number | 9C7 |
Tested applications | FC, ICC, IF, IHC, WB |
Reactivity | Human, Monkey, Mouse, Rat |
Isotype | Mouse IgG1 |
Immunogen | E.coli-derived human SHMT1 recombinant protein (Position: M1-S470). |
Antibody Type | Primary Antibody |
Concentration | Adding 0.2 ml of distilled water will yield a concentration of 500 μg/ml. |
Form/Appearance | Lyophilized |
Conjugation | Unconjugated |
MW | 53 kDa |
UniProt ID | P34896 |
Storage | Maintain refrigerated at 2-8°C for up to 2 weeks. For long term storage store at -20°C in small aliquots to prevent freeze-thaw cycles. |
Alternative names | chromosomal protein, Nonhistone, HMG4 antibody; Hi Read more... |
Note | For research use only |
Application notes | Western blot, 0.25-0.5μg/ml, Mouse, Monkey, Rat Immunohistochemistry (Paraffin-embedded Section), 2-5μg/ml, Human Immunocytochemistry/Immunofluorescence, 5μg/ml, Human Flow Cytometry (Fixed), 1-3μg/1x106 cells, Human. Add 0.2ml of distilled water will yield a concentration of 500ug/ml |
Expiration Date | 12 months from date of receipt. |
Flow Cytometry analysis of A431 cells using anti-SHMT1 antibody. Overlay histogram showing A431 cells (Blue line). To facilitate intracellular staining, cells were fixed with 4% paraformaldehyde and permeabilized with permeabilization buffer. The cells were blocked with 10% normal goat serum. And then incubated with mouse anti-SHMT1 Antibody (1 µg/1x10^6 cells) for 30 min at 20°C. DyLight®488 conjugated goat anti-mouse IgG (5-10 µg/1x10^6 cells) was used as secondary antibody for 30 minutes at 20°C. Isotype control antibody (Green line) was mouse IgG (1 µg/1x10^6) used under the same conditions. Unlabelled sample without incubation with primary antibody and secondary antibody (Red line) was used as a blank control.
IF analysis of SHMT1 using anti-SHMT1 antibody. SHMT1 was detected in immunocytochemical section of A549 cells. Enzyme antigen retrieval was performed using IHC enzyme antigen retrieval reagent for 15 mins. The cells were blocked with 10% goat serum. And then incubated with 5 µg/mL mouse anti-SHMT1 Antibody overnight at 4°C. DyLight®488 Conjugated Goat Anti-Mouse IgG was used as secondary antibody at 1:100 dilution and incubated for 30 minutes at 37°C. The section was counterstained with DAPI. Visualize using a fluorescence microscope and filter sets appropriate for the label used.
IHC analysis of SHMT1 using anti-SHMT1 antibody. SHMT1 was detected in paraffin-embedded section of human liver cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 µg/ml mouse anti-SHMT1 Antibody overnight at 4°C. Biotinylated goat anti-mouse IgG was used as secondary antibody and incubated for 30 minutes at 37°C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Western blot analysis of SHMT1 using anti-SHMT1 antibody. Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 30 ug of sample under reducing conditions. Lane 1: monkey liver tissue lysates, Lane 2: rat liver tissue lysates, Lane 3: mouse liver tissue lysates. After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150 mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with mouse anti-SHMT1 antigen affinity purified monoclonal antibody at 0.5 µg/mL overnight at 4°C, then washed with TBS-0.1% Tween 3 times with 5 minutes each and probed with a goat anti-mouse IgG-HRP secondary antibody at a dilution of 1:10000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for SHMT1 at approximately 53 KD. The expected band size for SHMT1 is at 53 KD.
FC, ICC, IF, IHC, WB | |
Human, Monkey, Mouse, Rat | |
Mouse | |
Monoclonal | |
Unconjugated |
FC, ICC, IF, IHC, WB | |
Human, Monkey, Mouse, Rat | |
Mouse | |
Monoclonal | |
iFluor647 |
FC, ICC, IF, IHC, WB | |
Human, Monkey, Mouse, Rat | |
Mouse | |
Monoclonal | |
PE |
FC, ICC, IF, IHC, WB | |
Human, Monkey, Mouse, Rat | |
Mouse | |
Monoclonal | |
APC |
FC, ICC, IF, IHC, WB | |
Human, Monkey, Mouse, Rat | |
Mouse | |
Monoclonal | |
HRP |